Operating instructions
47
1= Yes O= No*
Press the full set key to exit.
34 JAMMING
1 = Jamming generates a full alarm when
set
O= indicator only*
Press the full set key to exit.
(Jamming is signalled to the dialler out-
puts.)
35 MAINS FAILURE & PANEL LOW
BATTERY PREVENTS ARMING
1 = Mains failure or Panel battery failure
prevents arming.
O = Does not prevent arming*
Press the full set key to exit
36 REMOTE CONTROL UNSETS
ONLY IN ENTRY
1= Unset only after entry timer has been
started.
O= Unset not inhibited*
Press the full set key to exit.
37 DIALLER DELAYED
(20 second abort time)
1= Delayed O= Instant *
Press the full set key to exit
38 NO EXTERNAL BELL OR DIALLER IN
PART SET
(Internal bells only in Part Set).
1= Internal sounder only in Part Set.
O= Dialler and siren In both full or part set*
Press the full set key to exit
42 ENGINEER RESET
1= Engineer reset O= No*
Press the full set key to exit.
43 REARMING
new total of devices on that zone will be
displayed on the numeric LED's.
Press the Full Set key to exit.
02 PROGRAM DEVICES ONTO
ZONE 2
03 PROGRAM DEVICES ONTO
ZONE 3
04 PROGRAM DEVICES ONTO
ZONE 4
05 PROGRAM DEVICES ONTO
ZONE 5
06 PROGRAM DEVICES ONTO
ZONE 6
07 PROGRAM DEVICES ONTO
ZONE 7
08 PROGRAM DEVICES ONTO
ZONE 8
09 RADIO PANIC BUTTONS
To delete all Panic Buttons already on this
option press Part & 0 keys together.
To add a new device press the panic button.
The panel will emit 2 short blips to indicate
that it has read the panic button and LED 1
will indicate that one PA has been pro-
grammed in.
You can add up to 8 PA's to the panic zone
by simply pressing each one in turn.
Press the Full Set key to exit.
10 FIRE ALARM DEVICES
To delete all Fire sensors press Part & 0
keys together.
To add a fire sensor, short out the learn
jumper.
The panel will emit 2 short blips to indicate
that it has read the sensor and zone 1 LED
will indicate that one sensor has been
programmed in.
Up to eight sensors can be programmed
onto the fire zone by simply shorting out the
learn jumper of each one in turn.
Press the Full Set key to exit
11 REMOTE CONTROLS
To delete all Remote Controls press Part
& 0 keys together.
To add a remote control press the Panic
button. The panel will emit 2 short blips to
indicate that it has read the remote control
and LED 1 will indicate that one remote has
been programmed in.
You can add up to 8 remote controls by
simply pressing each one in turn.
Press the Full Set key to exit.
12 FULL SET EXIT TIME
1= 2 secs 2= 1O secs 3= 2O secs*
4= 3O secs 5= 45 secs 6= 1 min
7= 2 mins 8= 3 mins
Press Full Set to exit
* = FACTORY DEFAULT
13 PART SET EXIT TIME
1= 2 secs 2= 5 secs 3= 1O secs*
4= 15 secs 5= 20 secs 6= 30 secs
7= 1 mins 8= As full set exit time.
Press Full Set to exit
14 ENTRY TIME
1= 1 sec 2=10 secs 3= 20 secs
4= 30 secs* 5= 40 secs 6= 50 secs
7= 1 min 8= 2 min
Press Full Set to exit
15 BELL DURATION 1= Si-
lent 2= 15 secs 3= 2 mins
4= 3 mins 5=10 mins 6= 15 mins
7= 20 mins* 8=Continuous
Press Full Set to exit
1= none 2= once 3= twice 4=always*
Press the full set key to exit
44 RESTORE ENTIRE NV RAM TO FAC-
TORY DEFAULT VALUES
Short out the MEM link while keying in 44.
All zone LED's will come on, the panel will
emit a long bleep and will go out of engi-
neering mode into the day state.
WARNING: This will delete all detectors
from the system.
45 AUDIBLE RECEIVE MODE
The output from the receiver can be heard
on the panel loudspeaker.
Press the full set key to exit.
46 DISPLAY ENGINEERS LOG
Press keys 1 to 8 to view the last 8 events.
Most recent is displayed on key 1.
Key 9 shows the last "First to Alarm"
Press the full set key to exit.
47 CHANGE ENGINEERS ACCESS CODE
Key in a 4 digit code twice.
48 LEAVE ENGINEER MODE
If any devices have their tampers open,
the display shows which zones are tam-
pered and will generate an error beep.
The tampers must be restored before
leaving engineer mode by pressing 48
again.