Operating instructions

3 8
PROGRAMMING
1. Enter the engineers code 4 6 7 9
The Alarm led will flash slowly to indicate
that you are in the program mode.
2. Key in the two digit program number.
(The zone led's indicate which option is
set.)
3. Key in the option required
(The zone led's indicate your choice)
4. Press the Full Set key to exit that
program step.
5. When finished with programming key in
48 to exit engineer mode.
ERROR CORRECTION VIA PART SET KEY
If you accidently enter an engineer pro-
gram number and change an option value,
you can undo the change by pressing the
Part Set key before exiting the program
step via the Full Set key.
EXAMPLE: To set the Full set entry timer
to 1 minute.
Key in 4 6 7 9 The alarm indicator will
illuminate to indicate that you are now in
engineer program mode
Key in 1 2 To select Full set exit time
(program No. 12.)
Key in 6 To select the 1 minute option.
Zone 6 LED indicates your choice
Press the Full Set button to exit program
step.
Note: The Full set button must be pressed
to exit from each program step.
Until the Full Set button is pressed any
key press just changes your choice of
option.
Key in the next program Number you wish
to change.
When all programming is complete Key
in 48 to exit engineer mode
00 INVERT SIREN OUTPUT
Normally -ve applied in alarm.(0v in
alarm)
0 = -ve applied in alarm
1 = -ve removed in alarm
LEARNING DEVICES
When installing the system you may find
it easier to label each detector with its
zone number and learn them into the
panel before installation. Once pro-
grammed into the panel's memory, the
information will not be lost even when
power is removed from the panel.
01 PROGRAM DEVICES ONTO ZONE 1
Select program number 01. The num-
bered LED's will indicate how many de-
tectors are already on that zone. eg. if
LED's 1, 2 and 3 are lit then there are 3
devices on that zone.
To delete all detectors from that zone
press Part set & O keys together.
To add a detector to a zone, briefly short
out the learn jumper on the detector and
ensure that the learn pins are not left
permanently shorted.
The panel will emit 2 short blips to indi-
cate that it has learnt the detector and the
REMOTE ENGINEER RESET
FACILITY
When an alarm occurs which requires an
engineer reset, the user can call the Cen-
tral Station and obtain the access code
number to key in to the panel.
The panel zone LED's will illuminate ran-
domly.
From the LED's the Central Station opera-
tor can refer to a reference table and in-
struct the user what code to enter to per-
form an engineer reset.
Next time the alarm operates the reset
code number will have changed.