Programming instructions

5
Ambush Function Relay Terminals
1. Connect terminals 5 & 6 to a device able to properly
monitor normally open dry contacts for an ambush
condition.
2. Program the Relay for Ambush Function Activated (10)
using Program Function 67.
3. Set the Ambush Code using Program Function 66.
4. When the ambush code is entered followed by a valid
user code, the relay will close for 2 seconds.
Ambush Code
The ambush code defaults to 99. An error will sound if you
try to program a new user code starting with the ambush
code.
Users Associated for more than one group
If a user is associated with more than one group, all
associated groups would have to be disabled before the
user is disabled.
Service Code
User number 300 is the service code. Once the service
code is used, it is disabled. Function 9 is used to re-enable
the service code.
Keypad Lockout
Programmable number of attempts before keypad lockout.
Programmable lockout time.
Non-Volatile Memory
All programming is stored in non-volatile memory.
Error Checking
Extensive keypad program error checking reduces
likelihood of programming error.
Real Time Clock
Real time clock allows logging of events to within one
second accuracy. Unique feature (Functions 43/44) allows
speeding up or slowing down the clock providing long term
accuracy of the clock functions to within 3 minutes per year.
Programmable Relay Functions
Relay may be programmed to energize when one or more
selected events occur.
Programmable Timeout Functions
Timeout functions allow enabling/disabling users and
enabling passage mode for a time period without requiring
Group 1 Activated Features
Group 1 Member in puts lock in Passage
Mode Feature (88 & 89)
1. Use Function 88 to set an Open Time Window. The
lock will unlock (Passage Mode) when any Group 1
Member enters a code.
2. Use Function 89 to set the time to close the window.
Note: Passage Mode will have to be disabled each
night using Function 46 or schedule Function 73.
Example: Open window at 7:00AM using function 88,
Close Window at 8:30AM using function 89.
Lock will unlock when a member of group 1 enters their
code between 7:00AM and 8:30AM. If no group 1
member arrives between 7:00AM and 8:30AM, the lock
will stay locked all day.
Disarming a Burglary Control Panel (90 &
91)
1. Connect terminals 5 & 6 to a burglar control panel
with switch input for disarming.
2. Use Function 90 to set the time to open the window
allowing any Group 1 Member to close the relay
for 2 seconds. Note: Only 1 relay closure will occur even
if another member of group 1 enters their code.
3. Use Function 91 to set the time to close the window.
Note: The alarm panel will have to be armed at night by
the user or by an automatic schedule function of
the alarm panel.
Example: Open window at 7:00AM using program
Function 90, Close Window at 8:30AM using Function
91.
The relay will close, one time only, when a member of
group 1 enters their code between 7:00AM and 8:30AM.
Group 1 Member Enables Group 4 Users
(92 & 93)
1. Use Function 92 to set the time to open the window
allowing any group 1 member to enable group 4.
2. Use Function 93 to set the time to close the window.
Note: Group 4 will have to be disabled each night using
Function 17 or schedule Function 82. Example: Open
window at 7:00AM using Function 92, close window at
8:30AM using Function 93.Group 4 will be enabled when
a member of group 1 enters their code between 7:00AM