Programming instructions

24
Advanced User Programming
Add a User that is a member of Group 2 & Group 3
Program a User Code of 789 that is a member of Group 2. Refer to Function 2 (page 11). Use Function 2,
and add the new user as User 101 (Users 101-150 are members of Group 2):
Add User 101:
; 2 ; 1 0 1 ; 7 8 9 :
Make User 101 also member of Group 3 using Function 35:
; 3 5 ; 1 0 1 ; 2 3 :
Note: Although User 101 is by default a member of Group 2, Group 2 must be included when using Function 35 or the
Group 2 association will be removed.
Group 1 Activated Features
Add a User to Group 1
Program a User Code of 456789 that is also a member of Group 1. Use Function 2, and add the new user as
User 2 (Manager).
Add User 2:
; 2 ; 2 ; 4 5 6 7 :
Make User 2 a member of Group 1 by using Function 35:
; 3 5 ; 2 ; 1 :
Add Schedule that Opens the Lock (Passage Mode) when a member of Group 1 enters their code.
Program a schedule using Function 88 and Function 89 between the hours of 6 A.M. and 10 A.M. for all days of the week.
Enter the Open Window Time of 6 A.M.: ; 8 8 ; 0 ; 0 6 0 0 :
Enter the Close Window Time of 10 A.M.: ; 8 9 ; 0 ; 1 0 0 0 :
The Lock will now be put in passage mode IF User 2 (or any Group 1 User) enters their code between 6 A.M. and 10 A.M.
Th e Lock will have to be manually locked each night by entering the following command using Function 46.
Manually close the Lock by entering the following command:
; 4 6 :
The Lock can also be programmed to automatically close each night at 6 P.M. by adding a scheduled Lock Time using
Function 73:
Automatically (Scheduled Lock) close the Lock by entering the following command:
; 7 3 ; 0 ; 1 8 0 0 :
Other Group 1 Initiated (Manager) Functions include:
Disarming a Burglar Alarm (Relay Activation) See functions 90/91.
Group 4 Enable - See functions 92/93.
If the lock is programmed as above. The lock will be put in passage mode IF User 2 enters their
code between the hours of 6 A.M. and 10 A.M.
The example to add Users
to Group 2 and Group 3
has been selected due to
the fact that Group 1
Activated Functions
require that a member a
Group 1 enter their code
to activate the function.
Do not add general users
to Group 1 if Manager
Initiated Functions are to
be programmed -
Functions 88/89, 90/91
and 92/93.
Note:
Note:
To Change to a different
Group 1 Activated
Function.
Replace functions 88 & 89
(Passage Mode Enable)
with functions 90/91
(Burglar Alarm Disarm) or
92/93 (Group 4 Enable).