Programming instructions

11
1. New Master Code (User Number 1)
2. Add/Delete/Change User Codes 2-300
; 1 ; [ _ _ _ _ _ _ ] ; [ _ _ _ _ _ _ ] :
Users programmed with Function 2 will default to a Group
Association and a Program Level Ability as follows:
USER TYPE USER NUMBER DEFAULT
GROUP ASSOCIATION
PROGRAM
LEVEL ABILITY
Master Code 1 none 1, 2, 3, 4, Master
Manager Codes 2 - 6 none 1, 2, 3
Supervisor 7 - 11 none 1, 2
Basic User Codes 12 - 50 none none
Basic User Codes Group 1 51 - 100 1 none
Basic User Codes Group 2 101 - 150 2 none
Basic User Codes Group 3 151 - 200 3 none
Basic User Codes Group 4 201 - 250 4 none
Basic User Codes 251 - 298 none none
Non-Pass Code 299 none none
Service Code 300 none none
3. Disable User
; 3 ; [ _ _ _ ] :
(User Number)
; 2 ; [ _ _ _ ] ; [ _ _ _ _ _ _ ] :
4. Enable User
; 4 ; [ _ _ _ ] :
(User Number)
Enabling/Disabling Users (By User Number)
User Number must be between 2 and 300.
To delete a code, leave the User Code blank
User Code must be 3-6 digits
Master Code must be 6 digits-only.
NOTE: Following a power up, Function 1 (New Master Code), must be accessed before
any other programming function is permitted.
3
M
USERS
User Number must be between 2 and 300
NOTE: Will Enable/Disable users even if the user is associated with a enabled group.
2
User 299 is a Non-Pass Code. This is the only code that will initiate data transfer with the AL-DTM. This code can be assigned
program ability to allow printing the log to the handheld printer without allowing the user to pass through the door. This code may
be used to record a guard’s location in a building while “making his rounds”.
NOTE: