User`s manual
C2000 User Manual
Page 28 of 28
POWER SUPPLY
A.C. input voltage 16-19 V RMS
Battery float charge voltage 13.75 volts
LAN distribution voltage 13.75 volts
Max detector load per module 0.5 amps
Battery type Sealed lead acid
Battery capacity 6.5 amp hour
BACKUP TIMES (TYPICAL)
1 Terminal, no detectors 30 hours
1 Terminal, 500ma load 9 hours
REAL TIME CLOCK
Calendar length 256 years
Resolution 0.1 second
Trimmable accuracy 1 sec/week
REVIEW
Review size Standard 610 events
Expanded 4663 events
Review resolution 1 second
REVIEW EVENTS SAVED
Area open/close with User I.D. YES
Zone alarm/restore YES
Siren operation on/off YES
Auxiliary operation on/off YES
Zone isolation with User I.D. YES
General programming changes YES
Zone self-test failures YES
Walk-test results with User I.D. YES
Dialer telephone calls with # I.D. YES
Dialer errors YES
Lock operations YES
User log-in to terminals YES
User faults YES
System alarms YES
Time and date stamping of events YES
EXPANSION
Max number of zones 96 Zones
+ 96 Tampers
Max number of terminals 8
Max number of LAN modules 16
Max number of auxiliaries 56
Max internal siren drivers 6
Max external siren drivers 6
Serial printer interface Optional
Serial computer interface Optional
Securitel interface Optional
I.E.I. Fast (proprietary released) YES
Securitel (Ness S.I.U.) YES
Personal Dialing YES
Earth_Net Direct Line YES
REMOTE SERVICE FACILITIES
Installer code allowed YES
Master User code allowed YES
Remote item programming YES
Upload/download programming YES
Remote review download YES
Programming dump YES
Custom message display YES
Post User messages YES
CONCEPT PRODUCTS ARE DESIGNED AND
MANUFACTURED IN AUSTRALIA
By
Inner Range Pty. Ltd.
24 Laser Drive
Rowville. VIC 3178
PH: (03) 9753 3488
FAX: (03) 9753 3499