PART SPECIFICATIONS
Control Module
Dimensions Length 415mm
Width 210mm
Height 73mm
Maximum ambient temperature 50 degs C
Lid Tamper protection YES
Chassis Tamper protection YES
Chassis orientation ANY
Fabrication material Mild steel
DISPLAY & KEYS
Display types EL Backlit
32 Character
2x16 line
LCD
Scrolling rate 1-8 Chars/sec
Terminals beeper warnings 0.1 second
1.0 second
Continuous
Number of keys 20
Maximum code entry speed 10 keys/second
Terminal dimensions
Flush 185x120x10
Surface 185x120x31
User character set A to Z capitals
0 to 9 digits
# & ‘ () * + , - ./
: ; < = > ? @
space
USER CODES
Number of User Codes 96 or 480 (512)
User Code Length 1 to 8 digits
Combinations of 8 digit code 100 million
User name length 16 characters
ZONES
Number of Zones standard 16 Zones +
16 Tampers
expanded 96 Zones +
96 Tampers
Alarm levels per Zone 3 (seal, tamper,
alarm)
E.O.L. protection Dual resistor
Debounce time 0.5 sec
maximum
Max/min impulse volyage to AS-2201.1
Zone name length 24 characters
Pulse count Zones YES
No. of pulses 2.3 or 4
Pulse timer 10-255 seconds
AREAS
Area name length 16 characters
No. of individual arming areas 10
Zones per area 0 to 96
Area overlap allowed YES
Exit delay per area 0-99 seconds
Entry delay per area 0-99 seconds
No. of primary zones per area 6
Siren time per area 0-99 minutes
Siren time accuracy 1 second
SIRENS
Peak current for internal sirens 4 amps
Peak current for external sirens 4 amps
Recommd max. speakers per driver 2x8 ohm
Siren fuse detection YES
AUXILIARY OUTPUTS
No. auxiliaries per module
Control 2
Terminal 2
Zone expander 8
Maxi sustained current per Aux 200 milliamps
Max sustained voltage per Aux 13.7 volts
Auxiliary protection Detector Fuse
OTHER INPUTS
Low battery detection YES
A.C. mains fail detection YES
LAN fuse detection YES
Detector fuse detection YES
Siren fuse detection YES
Siren tamper detection YES
Terminal cabinet tamper YES
Control Module tamper YES
Zone Expansion module tamper YES
ACCESS CONTROL
Terminals per door 1
Maximum controllable doors 8
User codes (512) 480 useable
Magnetic card reader Optional
COMMUNICATIONS
Ademco Ext. Fast YES
Inner Range Fast YES
Ademco Contact I.D. YES