INTRODUCTION Congratulations on your purchase of a DSC PC2000 Burglar Alarm Control system. The PC2000 has been designed to give you the greatest possible flexibility and convenience in the use of your security system. This booklet is intended to serve as a handy reference and should be kept in a secure place. Your security system consists of a number of different components. One component is the DSC PC2000 control panel which will be mounted out of the way in a utility room or basement.
SYSTEMREFERENCE Zone Number Protected Area 1 2 3 4 6 8 Keypad Zone [1].[3] Keypad Zone [ *].[#I Master Code Number Programmed Code Numbers Monitoring Stalion Information Account # Telephone # Notes PRINTED IN CANADA COPYRIGHT 1966 DIGITAL SECURITY CONTROLS LTD. 1645 FLINT ROAD, DOWNSVIEW.
MASTER CODE The master security code is a 4 digit code which is supplied at the time of installation. The master code is entered from the keypad and is used for arming and disarming the security system, for programming additional security codes and for changing other features. All keypad entries are made by pressing only one key at a time, with exception of “KEYPAD ZONE” activation. z ‘. ARMING .d* Close all protected doors and windows and stop movement in areas covered by motion detectors.
To shunt zones, enler [ *I,[ 11 and the zone number(s) to be shunted. To remove all shunts, enter [*],[l],[O]. The ‘ZONE’ lights which are on indicate shunted zones. Press [#) to return lo ‘READY’(arm/disarm mode). When the system is installed, the abilily to shunt certain zones may be eliminated. In this case, the ‘ZONE’ lights for those zones will not come on in response to the shunt command. The ‘SHUNT’ light is on as long as at least one zone is shunted. Do not unintentionally shunt zones when arming.
. ARMED light will come on indicating system armed. Ensure READY light on, enter 4 digit code. MEMORY light on means an alarm has occurred To display zone that caused alarm, press @I then &I. Zone light will come on indicating which zone caused alarm. ZONE light(s) when on in the normal operating mode indicate an open zone. eg: open door, window, etc. Refer to zone chart on keypad door for detailed zone information. SHUNT light will come 1 on when you by-pass a zone.
ALARM TEST Press I*] lhen [4] for a 4 second lest of the keypad lights, keypad sounder and sirens. This is a local lest only. A lest transmission to the monitoring station is not done with this command. PROGRAMMING ADDITIONAL SECURITY CODES Enter [*I&] and [master security code]. The ‘PROGRAM’ light will flash and the ‘ZONE’ lights will show which codes have already been programmed (up to 8 codes can be programmed from the keypad).
SPECIAL FUNCTION COMMAND The PC2000 can be programmed at the time the system is installed to operate other devices such as electric door strikes, door openers, electric lights, cameras, etc. by a command from the keypad. This special function is activated by pressing [s] then [7]. PROGRAMMING OTHER SYSTEM FEATURES Before any of the following functions can be programmed, enter [*I, [8] and [master code]. The ‘PROGRAM’ light will be flashing.
AUTO-TEST TRANSMISSION The PC2000 can be programmed, at the time of installation, to send a test code to the monitoring station at regular intervals. The frequency and time of test transmissions is set by the monitoring station and should not be changed without their knowledge. DURESS CODE The duress code feature must be programmed into the PC2000 at the time of installation.
LIMITED WARRANTY i. . Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfillment of any breach of such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment upon relurn of the equipment lo its factory.