8. Operation
Following operation is based on the assumption, that the reader is connected to the power module
2002 POW. This is especially referring to input 2, for which a push button is placed on the power
module and for the open-collector output 3, to which a relay is connected on the power module.
• Programming the Master Transponder
When configuring the Reader at first the Master Transponder has to be programmed.
Programming condition for the Master Transponder is initiated by pressing the push button until the LED
lights up and switches off again (appr. 1 s). Now the push button is to be released and the Master
Transponder must be brought close to the Antenna. The recognition of the Master Transponder is then
acknowledged by a three-fold lighting up of the LED.
The Reader is in programming condition for the Master Transponder for a maximum time period of 5
seconds. If during this length of time no Transponder is brought close to the Antenna, the Reader will
acknowledge this process by a five-fold lighting up of the LED followed by a return of the Reader to the
Reading Mode.
The previously as Master Transponder stored Transponder is only empowered to program further Key
Transponders. It cannot be stored as a Key Transponder.
A Master Transponder cannot be used for normal opening action.
Please mark your Master Transponder accordingly and keep it in a safe place.
• Storing of a new Master Transponder
In case the Master Transponder is lost, a new Transponder can be stored as Master Transponder. This
process will invalidate the previous Master Transponder.
If a Transponder used as Key Transponder is newly programmed to be Master Transponder it will lose its
function as a Key Transponder.
Previously stored Key Transponders will remain in the Reader’s memory, i. e. they will not be deleted by
programming a new Master Transponder.
• Programming of Key Transponders
In order to program new Key Transponders the previously stored Master Transponder has to be brought
close to the Antenna for read-in for at least 3 but no more than 10 seconds. The Reader will then change
to the Programming Mode for 10 seconds. This condition is signalled by a two-fold short lighting up of the
LED.
Every Transponder read during this length of time will be stored in the Reader as a valid key (Key
Transponder). Every recognized and stored Key Transponder will be acknowledged by a single short
lighting up of the LED. Previously stored Key Transponders will not be stored again and will thus not be
acknowledged (LED does not light up).
The 10 second time period for the programming mode will at times be newly started upon recognition of a
Key Transponder.
A Transponder previously stored as Master Transponder cannot be used as a Key Transponder.
• Adding of Key Transponders
If any Master Transponder is being read for more than 3 but less than 10 seconds,
the Reader will change
to the programming condition and all Transponders previously stored in the Reader will remain valid.
By doing this new Transponder numbers can be added and stored as Key Transponders to the numbers
already existing.
• Erasing all stored Key Transponders
If the Master Transponder is held close to the Antenna for longer than 10 seconds,
the Reader will delete
all stored Transponders and will change to the programming condition. The LED will light up twice after 3
seconds and twice again after 10 seconds. Then the Reader will start new programming of the Key
Transponders.
Single Transponders cannot be erased separately.
Caution: When putting the unit into operation for the first time its memory should be erased
completely, i. e. the Master Transponder should be brought close to the Antenna for at least 10
seconds.
6