User's Manual
SETTINGS
SETTINGS > CONFIGURATION > GENERAL
206 ENVOY™ TRANSCEIVER REFERENCE MANUAL
System Lock Override
The System Lock Override entry sets how various actions at the control point
interact with a system lock.
If you want the control point to:
• always override other PTT sources and system locks, select Always
• never override other PTT sources or system locks, select Never
• ask the user before overriding other PTT sources and system locks, select
Prompt
Default value: Prompt
Morse Timeout
The Morse Timeout entry sets the length of time from the last morse activity after
which PTT is released.
Range: 50 to 1000 msec
Default value: 250 msec
PTT Timeout
The PTT Timeout entry sets the length of time after PTT is held down for the
transceiver to cease transmission and switch to receive. This ensures that, even if PTT
is held down accidentally (because, for example, you are sitting on the handset),
power consumption is minimised and the transceiver is ready to receive calls.
Range: 1 to 30 min
Default value: 10 min
Units
The Units entry sets the default system of units for temperature and distance
measurements.
Available values: Metric, Imperial
Default value: Metric