User's Manual

CONNECTORS
CONNECTORS ON THE RFU
332 E
NVOY™ TRANSCEIVER REFERENCE MANUAL
Q line
The Q line switches the transceiver between data and voice modes, and stops the
transceiver from scanning. When a modem is connected, settings are chosen that are
suitable for data transmission.
Related links:
Serial data on page 332
Relay contact
The relay can be wired by a user to ring a bell or to sound a car horn. If a voice call is
received, the bell or horn sounds for 2 minutes. If it is an emergency call, it toggles on
and off three times per second, continuing for 5 minutes.
The contact can be configured via internal links to do one of the following in the case
of an alarm:
join pins 6 and 7 together (normal, not available when 600 balanced audio
output is used), or
switch pin 6 to ground, or
switch pin 6 to battery volts (A rail)
NOTE: The external alarm is not activated under certain values of the Alert
Tones entry in Settings > Calling.
Related links:
Alert Tones on page 216
Serial data
The serial data (RS232) connector can be used for controlling and monitoring the
transceiver, programming the transceiver settings, and sending and receiving message
calls.
The serial data connector may be used for a number of products:
None to be used when no external RS232 device is connected to the
transceiver
GPS to receive information from a connected GPS receiver
CICS to control and monitor the transceiver via the connected
computer