User's Manual

CALL TYPES AND FEATURES
CALL TYPES
404 ENVOY™ TRANSCEIVER REFERENCE MANUAL
Table 48: Information retrieved in a Codan Diagnostic Get Status call made
to a Codan HF transceiver
Information received Description
TXnn.n Battery voltage in transmit
TXnn.n Battery voltage in transmit
S1=nnn Signal strength of received call (dBµV)
S2=nnn Signal strength 2 sec after call was received (dBµV)
SWRn.n SWR of the antenna
Pnnn Power output of the transmitter (W)
Tnn Temperature (°C)
Table 49: Information retrieved in a Codan Diagnostic Get Status call made
to a Codan 9323 or 9360 transceiver
Information received Description
RX=nn.nV Battery voltage in receive
TX=nn.nV Battery voltage in transmit
S1=nnnµV Signal strength of received call (dBµV)
S2=nnnµV Signal strength 2 sec after call was received (dBµV)
GAIN=nnn RF gain on or off
SWR=n.n SWR of the antenna
PWR=nnnW Power output of the transmitter (W)
Table 50: Information retrieved in an open Diagnostic Get Status call
Information received Description
RXnn.n Battery voltage in receive
TXnn.n Battery voltage in transmit
S1=nn Signal strength of received call
SWR=n.n SWR of the antenna