Reference Manual

Table Of Contents
The Control List
2110 SSB Transceiver Reference Manual 201
ALE Golay Set the value of the Golay threshold used in Golay testing. For
more information see page 211, ALE Golay.
2
ALE Hangup ALL
Call
Set whether or not the initiator of an ALL call can hang up the call
to all linked stations. For more information see page 211,
ALE Hangup ALL Call.
Enabled
ALE LQA Average Select the way that LQA information will be used when recording
signal quality. For more information see page 211,
ALE LQA Average.
Both
ALE LQA Clear Clear the LQA information in the transceiver. For more
information see page 212, ALE LQA Clear.
ALE LQA Decay Set the length of time it takes for LQA information to artificially
decay, or switch this feature off. For more information see
page 212, ALE LQA Decay.
15 days
ALE LQA Exchange Exchange LQA information with stations during each call so that
the link quality can be assessed in both directions. For more
information see page 213, ALE LQA Exchange.
On
ALE LQA Mapping Set the mapping of LQA information according to its frequency.
For more information see page 213, ALE LQA Mapping.
Frequency
ALE Retries Set the number of times the transceiver retries a channel when
attempting to establish an ALE link before trying the next best
channel in the network. For more information see page 213,
ALE Retries.
1
ALE Selective Msg Set whether or not you can send a message with a Selective call
made in an ALE/CALM network. For more information see
page 213, ALE Selective Msg.
Enabled
ALE Silent Mode Prevent automatic ALE transmissions from the transceiver unit.
For more information see page 213, ALE Silent Mode.
Off
ALE Site Mgr Collect information on unknown ALE transceivers in the network.
For more information see page 214, ALE Site Mgr.
Off
ALE Soundings Set the status of the transceiver following a sounding. For more
information see page 214, ALE Soundings.
Default
Audio Volume Set the audio volume of the transceiver. 8
Auto Resume Listen Set the scan method used when scanning is switched on by the
Auto Resume Mode entry. For more information see page 215,
Auto Resume entries.
Leave as is
Auto Resume Mode Set the action performed when the Auto Resume Time ends. For
more information see page 215, Auto Resume entries.
Start scan
Auto Resume Time Set the length of time after scanning stops that the transceiver
performs the action set in the Auto Resume Mode entry. For more
information see page 215, Auto Resume entries.
2 minutes
Table 22: Entries in the Control List (cont.)
Name of entry Use this entry to... Default