The
time-out
duration is jumper
selectable
from 1 second to 8 hours. The positions of the jumpers
on the top (Through hole
component)
side of the
Transmitter
Main Board.
Table
2-1 shows the
time-out
duration in
minutes
for the
various
jumper settings
which
are
listed
as
enabled
(E: jumper
shorted - in) or disabled (D: jumper left open - out). The standard factory
setting
of 5
minutes
is
shown in bold type in
table
2-2.
Table
2-1
Time-Out-Timer
Settings
D = DISABLED (no solder jumper
installed),
E = ENABLED (solder jumper
installed).
Bold text
represents
default
settings.
TIME-OUT DURATION
(MINUTES)
J26 = E
J26 =
D
J26 =
E
J32
J31
J29
J28
J27 = D
J27 =
E
J27 =
E
E E E E 0.01 0.01 0.01
E E E D 0.02 0.03 0.01
E E D E 0.04 0.06 0.02
E E D D 0.08 0.12 0.05
E D E E 0.15 0.23 0.10
E D E D 0.31 0.47 0.19
E D D E 0.62 0.94 0.38
E D D D 1.25 1.88 0.75
D E E E 2.5 3.75 1.5
D E E D
5.0
7.5 3.0
D E D E 10 15 6.0
D E D D 20 30 12
D D E E 40 60 24
D D E D 80 120 48
D D D E 160 240 96
D D D D 320 480 192