UHF Amplifier Instruction Manual UT-3 406 - 512 MHz
4
Adjust
R36, the VSWR
alarm
adjustment, so that the
voltmeter
indicates
+5 Vdc for a
3:1 mismatch.
5 Put the 50 ohm load back on again. The
voltmeter
should read
approximately
0 Vdc.
6
Disconnect
the voltmeter.
3.6.2.5 Antenna VSWR Overload
1
Disconnect
the radio
communications
test set and so that the
amplifier
is
terminated
with an open circuit.
2
Monitor
the current from the
+9.5
Vdc supply.
3
Adjust
R38, the VSWR overload adjustment, clockwise
until
a
noticeable
drop in the
+9.5
Vdc current occurs.
4
Reconnect
the radio
communications
test set and, the
+9.5
Vdc current should return
to the previous level.
3.6.2.6
Procedure Verification
1
Verify
that the current drawn from the
+13.8
Vdc supply is less than 1.5 A and from
the
+9.5
Vdc supply is less than 1.2 A when
transmitting
full 8 W RF output
power.
2 Turn off the power to the transmitter.