65hm1735801aproductspecs
Table Of Contents
3
3、Measuring conditions 测试条件
3-1
Motor Position
电机姿势
出力轴水平放置
3-2
Power Supply
电 源
可调节直流稳压电源,确保测量时无疑问
3-3
Environmental
Temperature and
Humidity
温度和湿度
The test is made in principle of a temperature between+10℃
to+30℃,And at relative humidity between 30% and 95%.
原则上温度为 10℃-30℃,湿度为 30-95%。
4
、Electrical Characteristics 电气性能
4-1
No-load
speed
空载转速
200rpm±8%
At Rated voltage and No-load
额定电压及无负载下测试
4-2
No-load
current
空载电流
0.5 A max
At Rated voltage and No-load
额定电压及无负载下测试
4-3
Rated load
额定负荷
6N.m
At Rated voltage
额定电压下测试
4-4
Rated speed
额定转速
160rpm±8%
At Rated voltage and rated load
额定电压及负载下测试
4-5
Rated current
额定电流
5.5A ±8%
At Rated voltage and rated load
额定电压及额定负载下测试
4-6
Stall current
堵转电流
≈10(TBD)A
At rated voltage and shaft locked
额定电压及锁定电机轴条件下测试
4-7
Terminal
resistance
电枢电阻
0.8±10%Ω
Measure between terminals
端子阻抗
4-8
Insulation
resistance
绝缘电阻
50MΩ min
DC500V between lead wire and case
在导线与机身之间加 DC500V 直流电压
4-9
Withstand
Voltage
耐压
0.5mA MAX
AC 600V /1s between lead wire and case
在导线与机身之间加 AC600V(1s)交流电压