5.5HM13950-01AProductSpecs

6
5-5 Vibration
To be set with mutual agreement
经用户确认同意
Same or less
than limitation
sample
小于等于
度样品
6Environmental Tests:环境试验
6-1 Vibration Test
振动试验
The motor difference in comparison with initial performance should keep
within ±10% after motors subjected to the sine wave of 2 mm amplitude
and frequency sweep 16.7HZ in the X.Y.Z directions for 2 hours each
电机在 XYZ 三个方向经过振幅为 2mm,频率为 16.7HZ
的正弦波扫描振动各 2 小时后,其性能参照 4.1~4.9 允许±10%变化。.
6-2 Drop Test
跌落试验
The motor difference in comparison with initial performance should keep
within ±10% after motors packed in standard inner box, are dropped at
each of 6 planes of the box onto 10mm thick wooden plate from the height
of 50cm
电机装的标准包装箱内,6 个面分别从 50cm 高处向 10mm 厚的木板上
跌落一次,其性能参照 4.1~4.9 允许±10%变化
6-3 Storage Test
under high
temperature
高温贮存试验
The motor difference in comparison with initial performance should keep
within ±10% after motors exposed to +60℃for 48 hours. and the
n to
temperature/humidity of Item 2-3 for 24 hours.
电机放于+60℃环境中 48 小时,再在常温常湿下放置 24 小时,其性能
参照 4.1~4.9 允许±10%变化
6-4 Storage Tests
under low
temperature
低温贮存试验
The motor difference in comparison with initial performance should keep
within ±10% after motors exposed to -30℃ for 48 hours. and the
n to
temperature/humidity of Item 2-3for 24 hours
电机在-30℃环境中放置 48 小时,再在常温常湿下放置 24 小时,其性
能参照 4.1~4.9 允许±10%变化
6-5 Storage Test
under high
temperature/
humidity
湿
试验
The motor difference in comparison with initial performance should keep
within ±10% after motors exposed to +40℃/90% RH for 48 hours.
and
then to temperature/humidity of Item 2-3for 24 hours
电机在+40℃/90%湿度环境中放置 48 小时,再在常温常湿下放置 24
时,其性能参照 4.1~4.9 允许±10%变化