User`s manual

Setting Up - IBM Mainframe (zSeries)
AXIS 5570e / AXIS 5670e User’s Manual 39
Switched Major
Node Definitions
The example below shows how the print server PU, PATH, and LU
definitions may be coded in a switched major node definition.
* PU definition
* E07xxxxxx is the node ID set in Axis Network Print Server.
*
PU5570e1 PUADDR=04, X
PUTYPE=2, X
IDBLK=E07, X
IDNUM=nnnnn, X
MAXPATH=1, X
SSCPFM=USSSCS, X
USSTAB=USSMAST, X
VPACING=(0)
*
* Path definition
* xxxxxxxxxxxx is the 12 last digits of the MAC
* address of the Axis Network Print Server
*
PA5570e1 PATHDIALNO=0104xxxxxxxxxxxx, X
GID=1, X
PID=1, X
GRPNM=gggggg
*
* LU definitions. Use either LU5570e1 or LU5570e3
*
* LU type 1 (SCS)
*
LU5570e1 LULOCADDR=2, X
DLOGMOD=SCS5570e, X
VPACING=7, X
PACING=3
*
* LU type 3 (3270DS)
*
LU5570e3 LULOCADDR=2, X
DLOGMOD=DSC5570e, X
VPACING=7, X
PACING=3