User`s manual

The Test Button
208 AXIS 5570e / AXIS 5670e User’s Manual
Section 23 The Test Button
The test button is located on the front right hand side of the AXIS
5570e/AXIS 5670e and is used for:
Printing a test page to check the connection to the printer.
Printing a parameter list to see the print server’s current settings.
Performing a Factory Default of the print server.
If you want to change any of the parameters, use one of the methods
described in “Management and Configuration” on page 128.
Printing a Test Page Press the test button once to print a test page. The Test Page contains
basic information about the AXIS 5570e/AXIS 5670e. It is recommended
that you print a test page every time you have connected the print server
to a printer.
Printing a Parameter
List
Press the test button twice to print a parameter list showing the current
AXIS 5570e/AXIS 5670e settings. This list provides comprehensive details
of all the parameters and their current status. Refer to The Parameter List,
on page 216.
If you want to change any of the parameters, use one of the methods that
are described in Management and Configuration, on page 128.
Performing a Factory
Default
1. Remove the external power supply to switch off the print server.
2. Press and hold down the test button while you reconnect the external power
supply.
3. Continue to hold down the test button until the network indicator remains
constantly lit. This should take about 20 seconds.
4. Restart the print server by disconnecting and reconnecting the external
power supply
.
Important!
A Factory Default will reset all AXIS 5570e/AXIS 5670e parameters and settings to their
default values except:
Installed certificate
Private key