Specifications

44
INSTRUCTIONAL PROCEDURES
C. Engage hydraulic system. Flip switch to “compressor activation” switch. Let the compres-
sor run for several minutes to allow compressor to warm up. Flip “welder-generator activa-
tion” switch for welder/generator use.
CAUTION
DO NOT RUN THE COMPRESSOR IN A REVERSE ROTATION FOR PERIODS LONGER
THAN 5 SECONDS. CONTINUED OPERA TION IN THIS MANNER WILL RESULT IN
EXTENSIVE COMPRESSOR UNIT DAMAGE.
The safety shutdown switch should be wired in series with the solenoid that opens the flow of
the hydraulic oil to the compressor drive motor. In cases of high temperature and/or pressure,
the closing of the valve will stop the compressor operation.
Safety circuit testing for EAGLE 6 in 1
Safety circuit testing can be done in the following manner. Start the truck. Engage the com-
pressor. Take a screwdriver and touch the 1/16” allen head screw on the face of the tempera-
ture gauge and simultaneously touch the outside ring on the face of the gauge. This should shut
off the power to the solenoid of the hydraulics. Push the button in on the shutdown switch to
reset. Repeat the test with the pressure gauge if solenoid does not stop flow to compressor,
check wiring.