Specifications

42
INSTRUCTIONAL PROCEDURES
2. INSTALLING THE WIRING & CONNECTING THE HYDRAULIC HOSES
This unit is shipped from the factory with all necessary internal wiring installed. The only remaining
wiring necessary is the wiring needed to interface your power source with the BOSS
INDUSTRIES unit.
1. Connect red wire to battery 12VDC power.
2. The yellow wire should by spliced into 12VDC switched feed for the on/off switch per
the end-users location.
3. Connect black wire to ground.
4. The orange wire is used to activate on electronic speed control circuit if required.
Please contact the factory with engine specifications for further assistance.
CONNECTING THE HOSES
The hydraulic hoses to the compressor should be connected directly to the hydraulic control block.
The pressure “P” input line should be made from a good quality high pressure (min. 3000 PSI)
hydraulic hose 1” i.d. The return line to tank “T” can be made from a medium pressure (min. 1000
PSI) hydraulic hose 1-1/4” i.d. Care should be taken to see that the hoses are not installed with
kinks or bends that inhibit flow of the hydraulic oil. Lack of flow could result in damage to the motor
and compressor. Lastly check to make sure hoses are not in cont act with sharp objects or edges
that may fray, chafe or cut them over time. Secure all hoses with tie down straps or clamp s.
#16 SAE
"P" PRESSURE
IN PORT
#20 SAE
"T" TANK
OUT PORT
1/2" FNPT
AIR OUTLET
4-PIN WIRE HARNESS
CONNECTOR
M10097 FABCO HYD CONNECTION