Specifications

26
COMPRESSOR OPERATION
OPERATING CONDITIONS
The following conditions should exist for maximum performance of the compressor. . The truck
should be as close to level as possible when operating. The compressor will operate on a 15
degree sideward and lengthwise tilt without any adverse problems. Operation in ambient tempera-
tures above 100°F (38°C) may experience high temperature shutdown.
INITIAL START-UP
1. Start power source and allow time for warm-up.
2. Engage hydraulic system.
3. Engage the compressor by moving the compressor toggle switch to the “on” position. Let the
compressor run for several minutes to allow the compressor oil to warm-up before applying air
demand.
4. Engage the welder/generator by moving the welder/generator toggle switch to the “on” position.
Let the generator run until the speed is constant before applying an electrical load. See the
welder/generator manual for detailed functions of the Eagle welder/generator.
NOTE
THE EAGLE 6 IN 1 IS DESIGNED TO RUN MULTIPLE FUNCTIONS
SIMULTANEOUSLY. THE COMPRESSOR CAN BE RUN WITH EITHER THE
GENERATOR OR THE WELDER WITHOUT SACRIFCING OUTPUT ON EITHER
FUNCTION.