Specifications
List Price Book 20A • Effective March 1, 2009
Phone: 866-322-1237 • Fax Customer Support: 860-584-2136 • Fax Order Entry: 866-322-1233
2
Pricing/product description subject to change without notice
Schlage Electronic Lock Overview
Common Features
• ANSI Grade 1
• UL 10B and 10C Fire
• Four Standard “AA” batteries (4 “AAA” for KC2 trim)
• 80,000 cycles, 2-3 year battery life (40,000 cycles for KC2 trim)
• Mechanical key emergency override
• Handing is field reversible
• Optional event recording of mechanical key use (most models)
• Available in a variety of finishes and lever styles
• Weather resistant (magnetic stripe locks require EXT option)
Lock Types
Cylindrical Latchbolt
1/2" and 3/4" Latch
Mortise Latchbolt
3/4" Latch
Software Matrix Locking Solutions Audit/Event History SmarTime* Features Credentials
SNAP
KC2 ✔
–
Code
Software iButton
SMS KC2
Code
Express CM
✔✔iButton
Card
SMS
KC2 Code
Select
CM ✔✔iButton
CL Card
* SmarTime allows limiting access by hours/days and defining unlock/relock schedules
Lock Functions
Office
Lockset is normally secure. Inside lever always allows free egress. Two pushbuttons on inside housing may be
used to select a passage or secured status. Meets need for lockdown function for safety and security. (valid toggle
credentials on the exterior may also be used to change status).
Classroom/Storeroom
Lockset is normally secure. Inside lever always allows free egress. Valid toggle credentials on the exterior may be
used to change to a passage or secured status.
Privacy
Lockset is normally secure. Inside lever always allows free egress. Two pushbuttons on inside housing may be used
to select a privacy status. The ‘Privacy Enable’ pushbutton will disable normal electronic access from the exterior.
Opening the door or pressing the ‘Privacy Disable’ pushbutton on the inside housing deactivates the privacy status.
Apartment
Lockset is normally secure. Inside lever always allows free egress. Two pushbuttons on inside housing may be used
to select a passage or secured status. Opening the door or pressing the ‘Unlock’ pushbutton causes the lockset to
toggle unsecured. While toggled unsecured, the lockset can only be secured while the door is closed by pressing the
‘Lock’ pushbutton or using a normal credential on the exterior. Normal electronic access from the exterior is always
allowed.
Programmable
Locks & Trim