Specifications
12
Part 6 Gas Conversion
Gas Specifications
- Non UK Only:
- UK Only:
NOTE:
* The burner operating pressure is to be measured at the manifold test point with both burners
operating
at full setting. The operating pressure is ex-factory set, through the appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion. (Refer to the ‘Gas Conversion’ information for
details).
Natural Gas LP Gas (Propane)
Main Burner Injectors
Ø 2.10 mm Ø 1.30 mm
Pilot Burner Injectors
0.35 0.23
Low Fire Adjustment
1 turn out (ccw) ½ turn out (ccw)
Operating Pressure
1.0 kPa (*) 2.5 kPa (*)
Gas Regulator Cap
Screw
Main Burner Aeration
Shutter
Fully Open Fully Open
Natural Gas
(G20)
Propane
(G31)
Main Burner Injectors
Ø 2.10 mm Ø 1.30 mm
Pilot Burner Injectors
0.35 0.23
Low Fire Adjustment
1½ turns out (ccw) ½ turn out (ccw)
Operating Pressure
10 mbar (*) 26 mbar (*)
Gas Regulator Cap
Screw
Main Burner Aeration
Shutter
Fully Open Fully Open