Specifications
11
Part 6 Gas Conversion
Gas Regulator
NOTE:
The regulator supplied is convertible between
Natural Gas and LPG, but it’s outlet pressure is fixed
ex-factory and is NOT to be adjusted.
1. Ensure that the gas supply is turned ‘OFF’ at the
mains.
2. Unscrew the hexagonal cap (23 mm A/F) from
the regulator.
3. Un-clip the plastic pin from the cap, rotate the
pin and re-fit it back into the cap the correct
way for the gas type to be used. (Either ‘LP’ or
‘NAT’ should be visible on the flank of the pin
once re-fitted to the cap).
4. Screw the cap back into the regulator hand
tight only.
Gas Type Identification Label
On completion of the gas conversion, replace the
gas type labels located at:-
- The rear of the unit, above the gas connection.
- Beside the rating plate.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin
rotated for LPG
Commissioning
Before leaving the converted installation;
1. Check all gas connections for leakages using
soapy water or other gas detecting equipment.
2. Check the following functions in accordance
with the operating instructions specified in the
“Operation” section of this manual.
Light the Main Burners.
Check the Low Fire Burner Operation.
Check the High Fire Burner Operation.
Ensure that all the Controls operate correctly.
Ensure that the Operating Pressure remains
correct.
NOTE:
If for some reason it is not possible to get the
appliance to operate correctly, shut off the gas
supply and contact the supplier of this appliance.
WARNING:
D
O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.