Specifications
7
Lighting the Main Burners
1. Rotate the control knob anti-clockwise to the
position marked HIGH.
2. Manually light the main burner.
- hold the gas control knob depressed for
approx. 10 - 15 secs then release.
3. Once lit the main burner will be burning at full
rate. For a lower heat, push in the gas control
knob and turn fully anti-clockwise to the LOW
position.
4. Also for intermediate heat, position the control
knob between the HIGH and LOW positions.
5. Repeat Items 1 to 4 to light the second main
burner.
Racking System
The Rack System fitted to the Salamander is self-
supporting when withdrawn, to allow easy loading
of food. The installation of the rack is dependent on
the cooking function required.
Part 4 Operation
Operation Guide
1. Cobra Salamanders have been designed to
provide simplicity of operation and 100% safety
protection.
2. Improper operation is therefore almost
impossible, however bad operation practices
can reduce the life of the salamander and
produce a poor quality product. To use this
salamander correctly please read the following
sections carefully:-
Lighting the Main Burners.
Racking System.
Cooking Recommendations.
Description of Controls
The salamander has individual heat controls for the
left and right sides. Select the desired heat level
and allow a few minutes for the elements to heat
up.
Cobra salamanders provide two
independently controlled heat zones.
High speed grilling is provided by the two
infrared gas burners in the ceiling of the
grilling compartment.
The left hand and right hand gas control
knobs operate the left side and right side
burners respectively, independently of each
other.
Each burner is provided with flame failure
protection.
C
AUTION
:
This appliance is for professional use and
is only to be used by qualified persons.
Only qualified service persons are
allowed to carry out installation,
servicing or gas conversion operations.
Components having adjustments
protected (e.g. paint sealed) by the
manufacturer should not be adjusted by
the user / operator.
Gas Control Knobs
๐ OFF Position.
HIGH Flame.
LOW Flame.
Rack Handles
WARNING:
ALWAYS SET THE GAS CONTROL TO THE 'HIGH' POSITION WHEN
LIGHTING THE MAIN BURNER.
I
F THE MAIN BURNER GOES OUT DURING NORMAL OPERATION
OR FOR ANY REASON, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RE-LIGHT THE MAIN BURNER