Specifications

7
Lighting the Main Burners
1. Rotate the control knob anti-clockwise to the
position marked HIGH.
2. Manually light the main burner.
- hold the gas control knob depressed for
approx. 10 - 15 secs then release.
3. Once lit the main burner will be burning at full
rate. For a lower heat, push in the gas control
knob and turn fully anti-clockwise to the LOW
position.
4. Also for intermediate heat, position the control
knob between the HIGH and LOW positions.
5. Repeat Items 1 to 4 to light the second main
burner.
Racking System
The Rack System fitted to the Salamander is self-
supporting when withdrawn, to allow easy loading
of food. The installation of the rack is dependent on
the cooking function required.
Part 4 Operation
Operation Guide
1. Cobra Salamanders have been designed to
provide simplicity of operation and 100% safety
protection.
2. Improper operation is therefore almost
impossible, however bad operation practices
can reduce the life of the salamander and
produce a poor quality product. To use this
salamander correctly please read the following
sections carefully:-
 Lighting the Main Burners.
 Racking System.
 Cooking Recommendations.
Description of Controls
The salamander has individual heat controls for the
left and right sides. Select the desired heat level
and allow a few minutes for the elements to heat
up.
 Cobra salamanders provide two
independently controlled heat zones.
 High speed grilling is provided by the two
infrared gas burners in the ceiling of the
grilling compartment.
 The left hand and right hand gas control
knobs operate the left side and right side
burners respectively, independently of each
other.
 Each burner is provided with flame failure
protection.
C
AUTION
:

This appliance is for professional use and
is only to be used by qualified persons.

Only qualified service persons are
allowed to carry out installation,
servicing or gas conversion operations.

Components having adjustments
protected (e.g. paint sealed) by the
manufacturer should not be adjusted by
the user / operator.
Gas Control Knobs
OFF Position.
HIGH Flame.
LOW Flame.
Rack Handles
WARNING:
ALWAYS SET THE GAS CONTROL TO THE 'HIGH' POSITION WHEN
LIGHTING THE MAIN BURNER.
I
F THE MAIN BURNER GOES OUT DURING NORMAL OPERATION
OR FOR ANY REASON, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RE-LIGHT THE MAIN BURNER