3
Gas Supply Requirements
- Non - UK Only:
- UK Only:
NOTE: (*)
The burner operating pressure is to be measured at
the manifold test point with both burners operating
at full setting. The operating pressure is ex-factory
set and not to be adjusted, apart from when
converting between gases, if required. Refer to the
‘Gas Conversion Instruction Sheet’ for this appliance
for further details.
Gas Connection
Gas supply connection point is located at the back,
130 mm from right hand side of the appliance, and
entered from beneath the appliance.
Connection is ½ BSP male.
Part 2 Specifications
Model Covered in this Specification -
CS9 Gas Salamander.
General
A commercial heavy duty, wall mounted gas fired
infra-red grilling Salamander for a wide range of
foods. Cobra Salamanders feature independently
controlled heat zones for left and right side of the
cooking area.
Two high speed infrared surface combustion burners
in the ceiling of the cavity are independently
operated with the left and right hand side controls.
Each main burner is provided with flame failure
feature for ease of operation and safety. The main
burners are manually lit with each burner having LO
to HI settings to provide full cooking flexibility.
Rack supports have 4 fixed height positions offering
flat and angled rack positioning.
Cobra Salamanders come standard
with a crumb /
drip tray for collection of cooking grease and
crumbs from the cooking operations. The tray is
easily removed (slide out) for cleaning and to
provide easy cleaning access to the rear and sides
of the cooking area.
A Branding Plate is available as an optional
accessory item and provides a deep grooved /
ribbed cooking surface which can be used with this
racking system. Refer to the Replacement Parts List.
The Branding Plates can be fitted onto the standard
wire rack allowing ease of change as required
between menus.
Dimensions
CS9 Gas Salamander.
Natural (G20) Propane (G31)
Heat Input (nett)
8.8 kW 8.8 kW
Gas Rate
0.84 m
3
/hr 0.63 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating
Pressure
10 mbar 26 mbar
Gas Connection
1
/
2
” BSP Male
Natural Gas
LP Gas
(Propane)
Input Rating
31.5 MJ/hr 31.5 MJ/hr
(N.H.G.C.)
(29.850 Btu/hr)
(29.850 Btu/hr)
Supply Pressure
1.13 - 3.4 kPa 2.75 - 4.5 kPa
(4.5” - 13.5” w.c.) (11” - 18” w.c.)
Burner Operating
Pressure
1.0 kPa (*) 2.55 kPa (*)
(4.0” w.c.) (10.0” w.c.)
Gas Connection
½" BSP Male