Service manual

B
Appendix B: Gas Conversion
27
© Moffat Ltd, September 2008
Revision 1/
Moffat Cobra Series CS9 - Gas Salamander
Conversion Procedure
NOTE:
These conversions should only be carried out by qualified persons. All connections
must be checked for leaks before re-commissioning the appliance.
For all the following conversion instructions, the side panels have to be removed
(Remove the two screws at the bottom of each side panel).
All conversion details apply to both L/Hand and R/Hand burners.
For all relevant gas specifications refer to the table at the end of this section.
Main Burner Injectors
1. Ensure that the gas supply has been turned 'Off'.
2. Unscrew the main burner injectors (
1
/
2
” A/F).
3. Determine the correct injector sizes for the corresponding gas
type from the rating plate affixed to the right hand side panel
front bottom corner.
4. Replace with the correct size injectors.
Low Fire Adjustment
1. Remove the gas control knobs from the front of the unit.
2. Remove the 2 front control panels by removing the two screws
(per panel) located at the bottom of each panel.
3. Set the burner low fire adjustment. The low fire screw on the
gas control valve should be screwed fully in, then unscrewed by
the measurement shown in the 'Gas Specifications' table.
NOTE: The 'Low Fire Screw' should be sealed with coloured
paint on completion of the low fire adjustment.
Gas Type Identification Label
On completion of the gas conversion, replace the gas type
labels located at:-
- The rear of the unit, above the gas connection.
- Beside the rating plate.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off
the gas supply and contact the supplier of this appliance.
C
AUTION
:
Ensure that the Unit is isolated from the gas supply before commencing
servicing
Main Burner
Injector
Low Fire
Adjustment
Figure b1
Figure b2