Service manual

6
Service Procedures
17
© Moffat Ltd, September 2008
Revision 1/
Moffat Cobra Series CS9 - Gas Salamander
6.2 Replacement
6.2.1 Thermocouple
1) Remove control knob.
2) Undo the two screws at the bottom of the
control panel, and remove.
6.1.1 Control Panel
6.1 Access
Figure 6.1.1
Two screws
6.1.2 Side Panel
1) Unscrew and remove the two screws near the
bottom of the side panel to be removed.
2) Lift the side panel and remove from the
salamander.
Figure 6.1.2
Two screws
1) Remove the side panel (Refer Item 6.1.2).
2) Unscrew the thermocouple from the side panel
of the salamander and withdraw the thermo-
couple from the burner area.
3) Unscrew the thermocouple from the rear of the
gas valve and remove the thermocouple from
the salamander.
4) Replace and re-assemble the thermocouple in
reverse order.
Figure 6.2.1a
IMPORTANT:
WHEN SCREWING THERMOCOUPLE BACK INTO
THE GAS CONTROL, ONCE THREADED UP,
TIGHTEN UP ANOTHER ¼ TURN ONLY.
DO NOT OVER TIGHTEN.
Figure 6.2.1b
Thermocouple
Unscrew Thermocouple
from side wall and rear
of Gas Valve and remove.