Specifications
4 
Part 2  Specifications
 - United Kingdom: 
NOTE: 
(
*
) Measure burner operating pressure at manifold test point with two burners operating at full setting.   
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart 
from when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’ Section for further details). 
 - All Other Markets: 
NOTE: 
 Measure burner operating pressure at manifold test point with two burners operating at 'High Flame' 
setting. 
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, apart from 
when converting between gasses, if required. 
 TOWN GAS Only - Burner operating pressure is to be adjusted using the adjustable gas regulator  
supplied. 
 Refer to ‘Gas Conversion and Specifications’ section in this manual for further details. 
Natural Gas (G20)  Propane (G31) 
Griddle 
(each 300mm 
section) 
Oven  Open 
Burner
(each) 
Griddle 
(each 300mm 
section) 
Oven 
CR6  CR9  CR6  CR9 
Heat Input 
(nett) 
Nominal 
5.0 kW  5.0 kW  6.5 kW  7.5 kW  4.6 kW  5.0 kW  6.0 kW  7.5 kW 
Reduced 
1.7 kW  1.5 kW  1.1 kW  2.2 kW  1.5 kW  2.2 kW  1.05 kW  2.3 kW 
Gas Rate 
(nett) 
Nominal 
0.53 m
3
/hr 0.53 m
3
/hr 0.51 m
3
/hr 0.79 m
3
/hr  0.36 kg/hr  0.39 kg/hr  0.47 kg/hr  0.58 kg/hr 
Reduced 
0.18 m
3
/hr 0.16 m
3
/hr 0.14 m
3
/hr 0.23 m
3
/hr  0.12 kg/hr  0.17 kg/hr  0.09 kg/hr  0.18 kg/hr 
Supply Pressure 
20 mbar  37 mbar 
Operating Pressure (*) 
10 mbar (*) 28 mbar (*) 
Gas Connection 
3
/
4
” B.S.P. Male 
Open 
Burner
(each) 
Natural Gas  Town Gas (**) 
Input Rate (N.H.G.C.) 
 - each Open Burner 
22 MJ/hr  22 MJ/hr 
 - each 300mm Griddle Section 
20 MJ/hr  20 MJ/hr 
 - Static Ovens 
CR6 
24 MJ/hr  24 MJ/hr 
CR9 
28 MJ/hr  28 MJ/hr 
Supply Pressure 
1.13 - 3.40 kPa  0.75 - 1.50 kPa 
Burner Operating Pressure (*) 
1.0 kPa  0.63 kPa 
Gas Connection 
¾” BSP Male 
LP Gas (Propane) LP Gas / Butane 
Input Rate (N.H.G.C.) 
 - each Open Burner 
22 MJ/hr  22 MJ/hr 
 - each 300mm Griddle Section 
20 MJ/hr  20 MJ/hr 
 - Static Ovens 
CR6 
24 MJ/hr  24 MJ/hr 
CR9 
28 MJ/hr  28 MJ/hr 
Supply Pressure 
2.75 - 4.50 kPa  2.75 - 4.50 kPa 
Burner Operating Pressure (*) 
2.6 kPa  2.6 kPa 
Gas Connection 
¾” BSP Male 