Specifications
19 
Part 6  Gas Conversion
 - United Kingdom 
Category:  II
2H3P. 
Flue Type:    A
1.
NOTE: 
*  Measure burner operating pressure at manifold test point with two burners operating at ‘High’  
setting. Operating pressure is ex-factory set, through the appliance regulator and is not to be  
adjusted, apart from when carrying out gas conversion, if required. (Refer to the information in this 
section for details). 
Natural Gas (G20)  Propane (G31) 
Open Burner 
Burner Injector 
Ø 1.90mm  Ø 1.20mm 
Low Fire Setting 
¾ turn open c.c.w.  ¼ turn open c.c.w. 
Burner Aeration Setting 
16mm open.  16mm open. 
Griddle 
Burner Injector 
Ø 2.00mm  Ø 1.25mm 
Low Fire Setting 
5
/
8
 turn open c.c.w. 
3
/
8
 turn open c.c.w. 
Burner Aeration Setting 
Fully open.  Fully open. 
Pilot Injector 
0.35 0.23 
Oven 
CR6 
Model 
Burner Injector 
Ø 2.40mm  Ø 1.40mm 
Low Fire Screw 
Ø 1.00mm  Ø 0.60mm 
Burner Aeration Setting 
Fully open.  10mm open. 
Pilot Injector 
0.35 0.23 
Burner Injector 
Ø 2.50mm  Ø 1.50mm 
Low Fire Screw 
Ø 1.50mm  Ø 0.95mm 
Burner Aeration Setting 
Fully open.  Fully open. 
Pilot Injector 
0.35 0.23 
Supply Pressure 
20 mbar  37 mbar 
Burner Operating Pressure (*) 
10 mbar  28 mbar 
Gas Regulator Cap Screw 
CR9 
Model 