Handling
Don’t handling Lithium-ion Polymer Battery with
metalwork. Do not open, dissemble, crush or
burn battery. Ensure good ventilation/
exhaustion at the workplace.
Prevent formation of dust.
Information about protection against explosions
and fires: Keep ignition sources away- Do not
smoke.
Storage
If the Lithium-ion Polymer Battery is subject to
storage for such a long term as more than 3
months, it is recommended to recharge the
Lithium-ion Polymer Battery periodically.
3 months: -10℃~+40℃, 45 to 85%RH
And recommended at 0
℃
~+35
℃
for long period
storage.
The capacity recovery rate in the delivery state
(50% capacity of fully charged) after storage is
assumed to be 80% or more.
The voltage for a long time storage shall be
3.7V~4.2V range.
Do not storage Lithium-ion Polymer Battery
haphazardly in a box or drawer where they may
short-circuit each other or be short-circuited by
other metal objects.
Keep out of reach of children.
Do not expose Lithium-ion Polymer Battery to
Personal Precautions, protective equipment, and
emergency procedures
Restrict access to area until completion of
clean-up. Do not touch the spilled material. Wear
adequate personal protective equipment as
indicated in Section 8.
Environmental Precautions
Prevent material from contaminating soil and
from entering sewers or waterways.
Methods and materials for Containment
Stop the leak if safe to do so. Contain the spilled
liquid with dry sand or earth. Clean up spills
immediately.
Methods and materials for cleaning up
Absorb spilled material with an inert absorbent
(dry sand or earth). Scoop contaminated
absorbent into an acceptable waste container.
Collect all contaminated absorbent and dispose
of according to directions in Section 13. Scrub
the area with detergent and water; collect all
contaminated wash water for proper disposal.
Material Safety Data Sheet
Section 6- Accidental Release Measures
Section 7- Handling and Storage
Report No.: TCT170309M001
Page 5 of 10
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332