Specifications
3
Gas Connection
Gas supply connection point is located at the rear
of the appliance, approximately 215mm from the
left hand side and 535mm from the floor and is
entered from beneath the appliance.
Connection is ½ BSP male.
Dimensions
CB6 GAS BARBEQUE (600mm)
Part 2 Specifications
Model Covered in this Specification -
CB6 GAS BARBEQUE.
General
A commercial heavy duty, fully modular, gas fired
barbeque created for modular kitchens supplied in
a 600mm wide option. The barbeque is fitted with
branding grates and aluminised steel burners, with
individual ‘Hi'-'Lo' gas control to each burner. The
burners are fitted with piezo ignited permanent pilot
and flame failure protection for each burner.
Gas Supply Requirements
- Non - CE Only:
- CE Only:
Appliance Classification
Category: II
2H3P
(20, 30 / 37).
Flue Type: A
1.
NOTE: (*)
The burner operating pressure is to be measured at
the manifold test point with all burners operating at
the 'High Flame' setting. The operating pressure is
ex-factory set and is not to be adjusted, apart from
when converting between gases, if required. Refer
to the ‘Gas Conversion Instruction Sheet' for this
appliance for further details.
Natural Gas
LP Gas
(Propane)
Input Rating
66.0 MJ/hr 66.0 MJ/hr
(N.H.G.C.)
(62,500 Btu/hr)
(62,500 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
(4.5” - 13.5” w.c.) (11” - 18” w.c.)
0.95 kPa (*) 2.60 kPa (*)
(3.8” w.c.) (10.0” w.c.)
Gas Connection
½" BSP Male
Burner Operating
Pressure
Nat Gas
(G20)
Propane
(G31)
Heat Input (nett)
Nominal
18.0 kW 18.0 kW
Reduced
6.0 kW 6.4 kW
Gas Rate (nett)
Nominal
1.90 m
3
/hr 1.40 kg/hr
Reduced
0.63 m
3
/hr 0.50 kg/hr
Supply Pressure
20 mbar 30 / 37 mbar
Burner Operating Pressure
10 mbar (*) 26 mbar (*)
Gas Connection
½" BSP Male