Specifications
12
Part 6 Gas Conversion
Gas Specifications
- Australia / New Zealand Only:
- CE Only:
Appliance Classification
Category: II
2H3P
(20, 30 / 37).
Flue Type: A
1.
NOTE:
* - The burner operating pressure is to be measured at the manifold test point with two burners operating at
full setting. The operating pressure is ex-factory set and not to be adjusted, apart from when converting
between gases, if required. (Refer to the ‘Gas Conversion’ section for details.
Natural Gas LP Gas (Propane)
Main Burner Injectors
2.70 mm 1.65 mm
Pilot Burner Injectors
0.45 0.30
Low Fire Adjustment
1
1
/
4
turns out (ccw) ½ turn out (ccw)
Operating Pressure
0.95 kPa (*) 2.6 kPa (*)
Main Burner Aeration Shutter
Fully Open Fully Open
Gas Regulator Cap Screw
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Natural Gas (G20) Propane (G31)
Main Burner Injectors
2.70 mm 1.65 mm
Pilot Burner Injectors
0.45 0.30
Low Fire Adjustment
1
1
/
4
turns out (ccw) ½ turn out (ccw)
Operating Pressure
10 mbar (*) 26 mbar (*)
Main Burner Aeration Shutter
Fully Open Fully Open
Gas Regulator Cap Screw
Supply Pressure
20 mbar 30 / 37 mbar