Specifications
11
Part 6 Gas Conversion
Gas Type Labels
On completion of the gas conversion, replace gas
type labels located at:-
- The rear of the unit, above the gas connection.
- Beside the rating plate.
Commissioning
Before leaving the converted installation;
1. Check all gas connections for leakages using
soapy water or other gas detecting equipment.
2. Check the following functions in accordance
with the operating instructions specified in the
'Operation' section of the Installation and
Operation Manual.
Light the Pilot Burners.
Light the Main Burners.
Check the Low Fire burner operation.
Check the High Fire burner operation.
Ensure that all the controls operate
correctly.
Ensure that the operating pressure remains
correct.
3. Ensure any adjustments done to components
that have the adjustments / settings sealed (e.g.
paint sealed) are re-sealed.
NOTE:
If for some reason it is not possible to get the unit to
operate correctly, shut off the gas supply and
contact the supplier of this unit.
WARNING:
DO NOT USE A NAKED FLAME TO CHECK FOR GAS
LEAKAGES.