Specifications
4
Part 2 Specifications
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gases, if required.
(**) TOWN GAS Only - Burner operating pressure is to be adjusted using the adjustable gas regulator
supplied.
Refer to the ‘Gas Conversion and Specifications’ section in this manual for further details.
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side and
630mm from floor. It is reached from beneath the appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male thread (for all models).
LP Gas (Propane) LP Gas / Butane
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Input Rate (N.H.G.C.)
22 MJ/hr 20 MJ/hr 22 MJ/hr 20 MJ/hr
Supply Pressure
2.75 - 4.50 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
2.6 kPa
Gas Connection
¾” BSP Male
Natural Gas Town Gas
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Input Rate (N.H.G.C.)
22 MJ/hr 20 MJ/hr 22 MJ/hr 20 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*)
1.0 kPa 0.63 kPa
Gas Connection
¾” BSP Male