Model Covered in this Specification -
C6D [1] Cooktop 4 Open Burners.
C6C [1] Cooktop 2 Burners + 300mm Griddle.
C6B Cooktop 600mm Griddle.
C9D [1] Cooktop 6 Open Burners.
C9C [1] Cooktop 4 Burners + 300mm Griddle.
C9B [1] Cooktop 2 Burners + 600mm Griddle.
C9A Cooktop 900mm Griddle.
General
A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle
arrangement and is available on adjustable front feet and robust rear rollers. Five griddle options with 2
models of base unit are available. Fitted with 'Individual Flame Failure' Option (F) for each open burner.
(Standard for UK - Optional for Non UK) Griddles are fitted with pilot, flame failure and piezo ignition as stand-
ard. These cooktops have an easy clean stainless steel external finish.
Gas Supply Requirements
- Australia:
- New Zealand:
- United Kingdom:
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’ section for further details).
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Heat Input (net)
Nominal
5.0 kW 5.0 kW 4.6 kW 5.0 kW
Reduced
1.7 kW 1.5 kW 1.5 kW 2.2 kW
Gas Rate (net)
Nominal
0.53 m
3
/hr 0.53 m
3
/hr 0.36 kg/hr 0.39 kg/hr
Reduced
0.18 m
3
/hr 0.16 m
3
/hr 0.12 kg/hr 0.17 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
10 mbar (*) 28 mbar (*)
Gas Connection
¾” BSP Male
Natural Gas LP Gas (Propane)
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Input Rate (N.H.G.C.)
22 MJ/hr 20 MJ/hr 22 MJ/hr 20 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*) 2.6 kPa (*)
Gas Connection
¾” BSP Male
Natural Gas LP Gas
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Input Rate (N.H.G.C.)
22 MJ/hr 20 MJ/hr 22 MJ/hr 20 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*) 2.6 kPa (*)
Gas Connection
¾” BSP Male
[1] - Open Burner Options:-
F - With Flame Failure Protection.
- Standard Burners.