Specifications
19
Part 6 Gas Conversion
- All Other Markets
(*) Measure Burner operating pressure at manifold test point with two burners operating at 'High
Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, unless
when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator supplied.
Refer to ‘Gas Conversion and Specifications section of this manual for further details.
LP Gas (Propane) LP Gas / Butane
Open Burner
Burner Injector
Ø 1.30mm Ø 1.20mm
Low Fire Setting
¼ turn open c.c.w.
Burner Aeration Setting
16mm open. Fully open.
Griddle
Burner Injector
Ø 1.25mm Ø 1.20mm
Low Fire Setting
3
/
8
turn open c.c.w.
Burner Aeration Setting
Fully open.
Pilot Injector
0.23
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa (*)
Gas Regulator Cap Screw
Natural Gas Town Gas (**)
Open Burner
Burner Injector
Ø 2.10mm Ø 3.80mm
Low Fire Setting
¾ turn open c.c.w.
1 turn open c.c.w.
Burner Aeration Setting
16mm open. 16mm open.
Griddle
Burner Injector
Ø 2.00mm Ø 3.40mm
Low Fire Setting
5
/
8
turn open c.c.w. 1 turn open c.c.w.
Burner Aeration Setting
Fully open. Fully open.
Pilot Injector
0.35 0.60
Supply Pressure
1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*) 0.63 kPa(*)
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure)