Specifications

18
Part 6 Gas Conversion
- United Kingdom
Category: II
2H3P.
Flue Type: A
1.
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at the ‘High’
setting. Operating pressure is ex-factory set through appliance regulator and is not to be adjusted,
apart from when carrying out gas conversion. (Refer to ‘Gas Conversion’ section for details).
Natural Gas LP Gas
Burner Injector
Ø 1.90mm Ø 1.20mm
Low Fire Setting
¾ turn open c.c.w.
¼ turn open c.c.w.
Burner Aeration Setting
16mm open. 16mm open.
Griddle
Burner Injector
Ø 2.00mm Ø 1.25mm
Pilot Injector
0.35 0.23
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
10 mbar 28 mbar
Gas Regulator Cap Screw
Open Burner
Burner Aeration Setting
Fully open. Fully open.
Low Fire Setting
5
/
8
turn open c.c.w.
3
/
8
turn open c.c.w.