User manual
49 
Type ‘c’ messages for Chaining commands 
Function 
R/W 
Block 
Command 
Data 
Type 
Chaining 
Input 
r/w 
c 
inp 
1 byte 
0 = Off 
1 = On 
2 = Relay 
int 
Chaining 
Output 
r/w 
c 
out 
1 byte 
0 = Off 
1 = On 
int 
Chaining 
Loop 
r/w 
c 
hio 
1 byte 
0 = Off 
1 = output loop to 
input for external 
encryption 
int 
Chaining 
status –
describes if 
chaining 
input is 
active 
r 
c 
sta 
1 byte 
0 = Not Active 
1 = Active 
2 = Overflow 
int 
Chain 
Number 
r/w 
c 
cha 
0 - 9 
int 
Lowest 
Operating 
Frequency 
r/w 
c 
flo 
Frequency in MHz 
double 
Highest 
Operating 
Frequency 
r/w 
c 
fhi 
Frequency in MHz 
double 
Intermediate 
Operating 
Frequency 1 
r/w 
c 
fl1 
Frequency in MHz 
double 
Intermediate 
Operating 
Frequency 2 
r/w 
c 
fl2 
Frequency in MHz 
double 
Calibration 
point lowest 
r/w 
c 
pl1 
0 – 32 in 0.25dB 
steps 
int 
Calibration 
point 
intermediate 
1 
r/w 
c 
pl2 
0 – 32 in 0.25dB 
steps 
int 
Calibration 
point 
intermediate 
2 
r/w 
c 
pl3 
0 – 32 in 0.25dB 
steps 
int 
Calibration 
point highest 
r/w 
c 
pl4 
0 – 32 in 0.25dB 
steps 
int 
Transport 
Stream 
Switch 
r/w 
g 
osw 
Bit 2 Input 
Switch(0=ASI,1=Ch
aining) 
Bit 3 Output Switch 
(0=ASI, 
1=Chaining) 
Eg 0 = ASI in and 
out, 12 = Chaining 
in and out 
int 