User manual

Chapter 5: Maintenance and troubleshooting
98-129217-C Status signalling 138
08045 Antenna -
Startup
temperature too
low
The temperature in the antenna
is too low for the system to start
up
None. If the ambient
temperature is outside the
specified limits, the antenna
may not be able to start up
properly. Refer to the
installation manual for
temperature specifications.
08046 Timeout of
startup sequence
- No antenna or
antenna
temperature too
low
The start-up sequence of the
terminal has timed out because:
the antenna is not properly
connected, or
the antenna temperature is
too low to start up.
Check that the antenna cable is
properly connected at both
ends.
08048 All PoE ports
except port 1
are shut down
due to high
temperature
The temperature in the terminal
is too high. PoE port 2 is shut
down to reduce the
temperature.
Move the terminal to a cooler
location, or avoid using PoE on
port 2.
08049 Data rate
reduction due to
high temperature
The bit rate of the data channel
is reduced because the
temperature is too high.
Move the terminal to a cooler
location
0804B Illegal
combination of
antenna and
terminal
You are not using the right
combination of antenna and
terminal.
Only use the antenna(s)
intended for use with your
terminal.
0804C The selected
satellite is not
visible at
current GPS
position
The terminal is set up to use a
satellite that is not visible at the
current GPS position.
Enter the web interface and
select SETTINGS > Satellite
selection.
Then select Auto to let the
terminal automatically find the
satellite with the best signal, or
select a satellite visible from
your current position.
0804D Antenna firmware
image is missing
in terminal
The software is corrupt Upload new software to the
terminal. Refer to Uploading
software on page 100.
ID Event Text Explanation Remedy