User manual

Chapter 5: Maintenance and troubleshooting
98-129217-C Status signalling 136
08002 One or more
ports has PoE
disabled due to
power
limitations
The power supply to the
terminal has dropped critically.
PoE is disabled to ensure
enough power to the antenna.
Ensure a stable power supply to
the terminal.
08008 Antenna exceeds
voltage
threshold
The antenna voltage is either
too high or too low.
Check the cable to the antenna.
Contact your distributor if the
problem persists.
08009 Power Hold-up -
the terminal can
no longer power
the antenna
The power supply to the
terminal has dropped for too
long. The antenna does not
have enough power to function.
Ensure a stable power supply to
the terminal.
0800B PoE Overvoltage
protection is
activated
Overvoltage is detected in the
terminal. The terminal will be
shut down in 10 minutes.
Do not use the terminal.
Contact your distributor.
0800D Antenna
Overvoltage
protection is
activated
Overvoltage is detected in the
antenna. The terminal will be
shut down in 10 minutes.
Do not use the terminal.
Contact your distributor.
08010 Undervoltage has
been detected
The input voltage has dropped
below an acceptable level. The
terminal will be shut down in 10
seconds if the situation persists.
Ensure a stable power supply to
the terminal.
0801B Lost connection
to the GPS
receiver
Communication with the GPS
receiver in the antenna is lost.
Restart the terminal.
Contact your distributor if the
warning persists.
0801D Uploading
firmware to
antenna
New firmware is being
uploaded to the antenna.
The Event will be cleared when
upload has finished.
Contact your distributor if the
Event is not cleared within 5
minutes.
0802C Firmware update
still fails
after several
retries
The terminal was unable to
upload new firmware to the
antenna.
Contact your distributor.
0802D Firmware update
failed
The terminal was unable to
upload new firmware to the
antenna.
Reboot the terminal. Then
update the software again.
Contact your distributor if the
problem persists.
ID Event Text Explanation Remedy