Specifications

ELEC TRI CAL
CHAR AC TER IS TICS
121.5/243.0 MHz, 406.025 MHz
OP ER ATING FRE QUENCIES 121.5 & 243.0 MHz
+/-0.005%
406.025 MHz
+/- 2 KHz (ini tial)
+/- 5 KHz (5 years)
2 parts/10E9 in 100ms
MOD U LA TION AM PLI TUDE MOD U LA TION
(A3X)
BI-PHASE L
(G1D)
TRANS MITTER DUTY
CYCLE
CON TIN U OUS 440 mSec (+/-1%) or
520 mSec (+/-1%) ev ery
50 sec onds (+/- 5%)
PEAK EF FEC TIVE RA DI -
ATED POWER (PERP)
Min i mum 50mW (17dBm)
PERP for 50 hours at
-20C or 100mW EIRP
(20dBm) for 48 hours at
-20C.
5 Watts (+/- 2dB) PERP
or EIRP for 24 hours at
-20 C
OC CUPIED BAND WIDTH 25 KHz Max i mum 20 KHz Max i mum
OP ER ATING TEM PER A TURE -20C TO +55C -20C TO +55C
AU TO MATIC AC TI VA TION
FOR C406 Se ries ,
VE LOC ITY CHANGE OF
4.5 Ft./SEC OND
VE LOC ITY CHANGE OF
4.5 Ft./SEC OND
AUX IL IARY G-SWITCH AC-
TI VA TION FOR C406-2HM,
5 AUX IL IARY G-SWITCHES
AC TI VATE AT 12 G’s IN
AD DI TION TO THE MAIN
G-SWITCH ,
5 AUX IL IARY G-SWITCHES
AC TI VATE AT12 G’s IN
AD DI TION TO THE MAIN
G-SWITCH
EN VI RON MEN TAL
CHAR AC TER IS TICS
121.5/243.0 MHz 406.025 MHz
TEMP (STOR AGE) -55°C TO +85 °C -55°C TO +85 °C
TEMP (OP ER ATING)
-20°C TO +55 °C -20°C TO +55 °C
AL TI TUDE 55,000 FEET 55,000 FEET
ARTEX AIRCRAFT SUPPLIES DOCUMENT #570-5000
04/04/02 PAGE 5-2