User's Manual
Table Of Contents
- Cables and Connections
- Video and Audio
- DC Power
- Antennas
- Control Cable
- Installation Notes
- Connections
- Square down-converter
- New Style Barrel down-converter
- Diversity, Antenna Positioning and Use of Down Converters
- Video Output Connection
- Audio Connection
- DC Power
- Control Cable
- Data Connection
- Installation Notes
- Applying power to the Solo Receiver
- Applying power to the transmitter
- Switch On RF on the transmitter
- Changing Configuration
- Standby
- Diagnostic On Screen Display
- Using the OSD as a Set-up / Diagnostic Tool
- Using the transmitter Range Mode Button
- Using the SOLBAT
- Charging the SOLBAT
- Connections
- Amplifier Connection
- DC Power and Control Cable
- Antennas
- Installation Notes
- Connections
- RF Connection
- DC Power
- Antennas
- Installation Notes
- Output Frequency (MHz)
- Bandwidth Mode
- Audio
- Default Transmit Mode
- Scrambling
- File Options
- Advanced TX Controller Window
- Output Frequency (MHz)
- Modulation Bandwidth
- Modulation Output
- Narrow Band FEC
- Narrow Band Guard Interval
- Narrow Band Modulation
- DVB-T Service Name
- DVB-T FEC
- DVB-T Guard Interval
- DVB-T Modulation
- Output Attenuation
- Video Input
- MPEG Mode
- MPEG2 GOP Length
- MPEG4 Encoding Mode
- MPEG4 Frame Rate
- Video Bitrate
- Horizontal resolution
- Audio Encoder
- Audio Input Level
- Unit Name
- Sleep Mode
- Data
- Data Baud Rate
- Chaining Input
- Chain Number
- Current Config
- Scrambling
- Video Locked (Status Only)
- Software Version (Status Only)
- FPGA Version (Status Only)
- Serial Number (Status Only)
- Chaining (Status Only)
- Options
- File
- Bandwidth Mode (Narrowband or DVB-T)
- Input Frequency (MHz)
- Service Name
- Descrambling
- File Options
- Advanced RX Controller Window
- Narrowband / DVB-T
- Input Frequency
- Down converter LO
- Down converter LO side
- OFDM Bandwidth
- OFDM Guard Interval
- OFDM Mode (Status Only)
- OFDM FEC (Status Only)
- Input SNR (Status Only)
- BER Pre Viterbi (Status Only)
- BER Post Viterbi (Status Only)
- Input Level (Status Only)
- Demod Lock Status (Status Only)
- Data
- Data Baud Rate (Status Only)
- Input Line Standard (Status Only)
- Power Up Line Standard
- NTSC Mode
- Blue Screen on Fail
- Unit Name
- Descrambling
- Decoder Lock Status (Status Only)
- Current Config
- Serial Number (Status Only)
- Software Version (Status Only)
- FPGA Version (Status Only)
- Chaining
- Options
- File
- IP Address
- Multicast Address
- Port Number
- TTL
- SAP Address
- SAP / SDP Data
- Record to file
- Enable audio
- Close window
- Signal Level Descriptions
- Signal Quality Descriptions
- Starting a Scan
- Setting the Scan Range
- Quick Scanning Stage
- Service Scanning Stage
- Completed Scan
- Front Panel Control
- Control Commands
- Original OSD Mode
- OSD Timeout
9
3
Type ‘c’ messages for Chaining commands
Function R/W Block Command Data Type
Chaining
Input
r/w c inp 1 byte
0 = Off
1 = On
2 = Relay
int
Chaining
Output
r/w c out 1 byte
0 = Off
1 = On
int
Chaining
Loop
r/w c hio 1 byte
0 = Off
1 = output loop to
input for external
encryption
int
Chaining
status –
describes if
chaining
input is
active
r c sta 1 byte
0 = Not Active
1 = Active
2 = Overflow
int
Chain
Number
r/w c cha 0 - 9 int
Lowest
Operating
Frequency
r/w c flo Frequency in MHz
double
Highest
Operating
Frequency
r/w c fhi Frequency in MHz
double
Intermediate
Operating
Frequency 1
r/w c fl1 Frequency in MHz
double
Intermediate
Operating
Frequency 2
r/w c fl2 Frequency in MHz
double
Calibration
point lowest
r/w c pl1 0 – 32 in 0.25dB
steps
int
Calibration
point
intermediate
1
r/w c pl2 0 – 32 in 0.25dB
steps
int
Calibration
point
intermediate
2
r/w c pl3 0 – 32 in 0.25dB
steps
int
Calibration
point highest
r/w c pl4 0 – 32 in 0.25dB
steps
int
IQ Trim
mode
S/W V3.3+
r/w c itr 0- normal operation
1 – Set single/lower
2 - set mid point
3 – set upper point
int
I trim Value
S/W V3.3+
r/w c iqi -128 to +127
Signed but set and
read as unsigned
(255 = -1)
int
Q Trim Value
S/W V3.3+
r/w c iqq -128 to +127
Signed but set and
read as unsigned
int