Specifications

D17XX OEM Integration v0.1
32
www.cobham.com/domo
Domo Limited doing business as Cobham Surveillance
2 = Node2
3 = Node3
4 = Node4
5 = Node5
6 = Node6
7 = Node7
Advanced
Commands
mflo
Flow Rate
Flow Rate
double
Config
Group: RF
Command
Name
FCON
Type
R/W
Scope
Options
Main
Commands
gloc
Lock
RF Lock
intList
Read
Only
Global
0 = No
1 = Yes
ofre
Modulation
Frequency
Freq
double
Config
MHz
ohls
Output
Level
Select
RF Hi/Lo
intList
Config
0 = Low
1 = High
olev
Output
Level High
Atten High
integer
Config
dB
ollv
Output
Level Low
Atten Low
integer
Config
dB
oout
Modulation
output
RF Out
intList
Config
0 = Off
1 = On
owid
Modulation
Bandwidth
B/W
intList
Config
0 = 2.5MHz
1 = 3.0MHz
2 = 3.5MHz
Group:
Scram
Command
Name
FCON
Type
R/W
Scope
Options
Main
Commands
zae5
AES
Scrambling
Key - upper
128 bits
used in
AES256
only
AES Key 2
hexString
Write
Only
Config
zaes
AES
Scrambling
Key - lower
128 bits
AES Key 1
hexString
Write
Only
Config
zclr
Clear Keys
Clear
intList
Global
0 = No
1 = Yes
zdes
Scrambling
Descram
intList
Config
0 = Off
1 = Invalid
Option
2 = Invalid
Option
3 = Invalid
Option