The output power needs to be checked over a range of frequencies automatically pre-
defined in the software relating to the particular type of the unit. Using the o and p keys to
adjust the output power, confirm on the Power Meter that the minimum RF Output the
D17XX can provide is >21.5dBm, regardless of Tera Term setting.
Adjust the output power at the first trim frequency to 20.0dBm ± 0.25dB in Tera Term.
Press x and proceed to the next trim frequency.
Perform the same test for each trim frequency.
Press x after the last Power Calibration Frequency to proceed to the Shoulder
Performance section.
5. Spectrum Verification
Disconnect the Power Meter Sensor and reconnect the RF Out to the Spectrum
Analyser.
Set the Spectrum Analyser Span to 10MHz, Res B/W to 10KHz, and Video B/W to
30KHz.
Confirm the Spectrum Analyser display is similar to that shown in Figure 11.
Figure 11: Shoulder performance
Measure and confirm the level between the display top and the Shoulder is >25dB.
This test only needs to be carried out at the first trim Frequency.
6. Set RTC Clock
With the D17XX powered
down
insert a CR1220 battery into J13 and power up the unit.
Open a web browser and navigate to the IP address of the D17XX PCB (See section 10
below)