User's Manual

function base on the RSSI, which is related to different distance between the
paired BWC and In-Car Trigger, to turn on/off BWC’s recording remotely:
If the RSSI is lower than a threshold which is considered that the officer
leave the patrol car (EX. for examining the crime scene), In-Car Trigger
will remotely turn on BWC’s recording automatically.
If the RSSI is higher than a threshold which is considered that the officer
sit back to the driver seat of patrol car, In-Car Trigger will remotely turn
off BWC’s recording automatically.
In Test UI, In-Car Trigger Status window display the listed configuration of
proximity trigger function:
Proximity Trigger EN: A radio box that indicate the proximity trigger is
enabled or not. It will be set if proximity trigger function is enabled.
InCarDelay: A time delay parameter for considering the BWC is located in
the patrol car. Refer to the following description on InCar Thres
parameter.
InCar Thres: The upper RSSI threshold, BWC would be considered
located in the patrol car if the RSSI is higher than this value for defined
InCarDelay secs.
OutCarDelay: A time delay parameter for considering the BWC is located
in the patrol car. Refer to the following description on OutCar Thres
parameter.
OutCar Thres: The lower RSSI threshold, BWC would be considered
located out of the patrol car if the RSSI is lower than this value for defined
OutCarDelay secs.
All the parameters above for proximity trigger configuration could also be
configured under the In-Car Trigger Control window of Test UI: