User guide

9035-OM (V4.4) 9035 PRODUCT MANUAL 2-9
Installation and Setup Installing a Rear I/O Module
RM20-9035-G
Provides the following connections:
HD/SD-SDI coaxial input (SDI IN)
Analog Y/composite, Pr/C, and Pb coaxial inputs
(Y/Cmpst, Pr/C, and Pb, respectively)
Eight dedicated AES coaxial audio inputs
(AES IN 1 thru AES IN 8)
Note: For AES IN 1 thru AES IN 4 on RM20-9035-G
Rear I/O Module to function as inputs, AES I/O
switches S11 S14 must be set to Input
(factory default). See Setting I/O Switches for
AES I/O (1-4) Ports (p. 2-1) for more
information.
Eight analog balanced audio inputs (AN-AUD IN 1
thru AN-AUD IN 8)
Eight dedicated AES coaxial audio outputs
(AES OUT 1 thru AES OUT 8)
Two buffered SDI coaxial outputs (SDI OUT)
RM20-9035-H Provides the following connections:
HD/SD-SDI coaxial input (SDI IN)
Two HD/SD-SDI reclocked input copies
(RCK OUT 1 and RCK OUT 2)
Four AES I/O coaxial input/outputs (AES I/O 1 thru
AES I/O 4; I/O function of each connection is
user-configurable)
RS-485 metadata/LTC I/O output (DOLBY META)
Two buffered SDI coaxial outputs (SDI OUT 1 and
SDI OUT 2)
Table 2-1 9035 Rear I/O Modules continued
9035 Rear I/O Module Description