Alarm LED
Status OK LED
Comm Activity LED
Alarm Mute/Bootload Button
Alarm Config Jumper
Fan Board Connector Edge
Figure 12. MFC-8320 Card Edge Controls
MFC-8320 Alarm Configuration Jumper
The Alarm Configuration Jumper enables or disables the audio alarm signal. The Alarm LED will still
be lit if alarm conditions are occurring, but the audio will be off.
Set to position 1-2 to enable the audio alarm
Set to position 3-4 to disable the alarm
Alarm Mute Button
If the optional CFM-8320 Cooling Fan Module is installed, there is an Alarm Mute Button on the right
side of the frame door front. If a card, that is in the frame, is reporting an error, pressing the Alarm
Mute Button will mute the audio alarm until another fault condition occurs.
Remote Control Networking Features
This section includes instructions for installing the MFC-8320-N controller card for the CFM-8320
module.
Note: Refer to Cobalt
®
reference guide COMPASS Remote Control User Guide
(PN 9000RCS-RM) for thorough information and step-by-step instructions for setting up network
remote control of COMPASS cards using DashBoard and the Network Controller Card. This
guide provides information for setting up remote control using MFC-8320-N Network Controller
Cards.
Installing the Network Controller Card
Perform the physical installation of the MFC-8320-N controller card for the CFM-8320 using the steps
provided in the section Installing the Controller Card of this manual. Once the controller card is
installed, you can proceed to the section below to set up the Ethernet connection for your card.