User manual
Appendix B
142
Upgrading your RaQ 3
The RaQ 3 unit is a single rack-unit (1RU) enclosure. Before you
purchase a component to add to the RaQ 3, ensure that the component
fits into the allocated space:
• The DIMM modules must be less than 1.5 inches (38.1 mm) tall
and less than 0.158 inches (4.0 mm) thick.
• The PCI expansion slot has been designed to accommodate the
PCI standard short card form factor, with some additional space for
longer cards. The PCI card must be less than 10.5 inches (267 mm)
long.
Note: The PCI expansion slot is avalaible on the RaQ 3i
configuration only.
To add memory or a PCI expansion card to the RaQ 3:
Opening the RaQ 3
Warning: You MUST power down the RaQ 3 before opening
the unit.
1. Power down the RaQ 3. See “Powering down” on page 138.
2. Unplug the RaQ 3.
3. Remove the power cord from the rear of the RaQ 3. The cable is
located beside the power switch. See Figure 2 on page 4.
Note: If the RaQ 3 is mounted on an equipment rack, remove
the RaQ 3 from the rack and take it to a service area. Do not
attempt this upgrade while the RaQ 3 is still in the equipment
rack.
4. Unscrew the top cover. Ten screws hold the the top cover in place.
The screws are labeled 1 through 10 in Figure 43.